I was a little confused as I was running Emulate 5000 v20, which on Windows XP should had provided support for version 12 to 20. After confirming this fact in the product’s release notes, I tried another slots and was able to chose from versions 12-20. Once that issue was resolved, I ran into a second issue. As I was emulating a CompactLogix file, and those processors are located in slot 0, I attempted to put my virtual processor in slot 0 of the virtual backplane, However, when I right clicked on slot 0 the only versions available were v17 – v20, but my client’s file was version 16. After a painfully long re-install of RSLE, I was indeed able to browse to my emulated processor, update my shortcut, and test the ViewStudio project. So, I first restarted the RSLE service, and when that didn’t work I restarted my virtual PC. With it still not working, I headed of to the Rockwell Knowledgebase and the only helpful advice it had was to reinstall RSLinx Enterprise. However, in this case when I proceeded to update my RSLE shortcut, browsing the virtual backplane didn’t display my emulated processor? Once this is done, I open the PanelView Plus project in ViewStudio and modify the RSLinx Enterprise (RSLE) shortcut to point at the emulator. To test these files together I usually change the CompactLogix file into an Emulator file in RSLogix 5000, and then download it to Emulate 5000 (a processor emulator for RSLogix 5000.) Last week a client sent me a CompactLogix file and PanelView Plus file to review.